Due to a problem of the Intel® Quartus® Prime Pro software version 18.1.1 and later, M20K dual-port RAM data may be corrupted in the first read operation or the first write operation when using rd_addressstall or wr_addressstall in the Intel Stratix® 10 device. This problem is observed only when rd_addressstall or wr_addressstall is initially high from the beginning of user mode and is kept high until the 1st read operation or the 1st write operation.
- Toggle rd_addressstall to low with a valid read address for at least one read clock cycle when using rd_addressstall
- Toggle wr_addressstall to low with a valid write address for at least one write clock cycle when using wr_addressstall
- A patch is available to fix this problem in the Intel® Quartus® Prime software version 19.3
This problem has been fixed since the Intel Quartus Prime Pro software version 20.3.