Article ID: 000074873 Content Type: Troubleshooting Last Reviewed: 05/01/2020

Is the weak pull-up feature supported in bank 3C of Intel® Stratix® 10 GX 400 and SX 400 devices?

Environment

  • Intel® Quartus® Prime Pro Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    Although documented as supported in Intel® Stratix® 10 General Purpose I/O User Guide and allowed in Intel® Quartus® Prime Pro Edition software version 20.1 and earlier, the weak pull-up feature is in fact not supported in bank 3C of Intel® Stratix® 10 GX 400 and SX 400 devices.

    Resolution

    The weak pull-up option for bank 3C is scheduled to be removed starting with the Intel Quartus Prime Pro Edition software version 20.2.

    Related Products

    This article applies to 1 products

    Intel® Stratix® 10 FPGAs and SoC FPGAs