Article ID: 000076630 Content Type: Error Messages Last Reviewed: 02/08/2023

Error (12077): Node instance "altera_mult_add_rtl2" instantiated with unknown parameter "ACCUM_SLOAD_PIPELINE_SCLR"

Environment

  • Intel® Quartus® Prime Standard Edition
  • DSP
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    Due to a problem with the Cyclone® V FPGA ALTMULT_COMPLEX IP in the Intel® Quartus® Prime Standard Edition Software version 17.0, you might see the error above during compilation if the IP variation file type is VHDL.

    Resolution

    To work around this issue, use the Verilog IP variation file type.

    This problem is fixed starting with the Intel® Quartus® Prime Standard Edition Software version 18.0.

    Related Products

    This article applies to 1 products

    Cyclone® V FPGAs and SoC FPGAs