Article ID: 000076633 Content Type: Install & Setup Last Reviewed: 12/23/2022

error: couldn't read file "tod/tod_inc.tcl": no such file or directory

Environment

  • Intel® Quartus® Prime Pro Edition
  • Low Latency Ethernet 10G MAC Intel® FPGA IP
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT

    Critical Issue

    Description

    Due to a problem in Intel® Quartus® Prime version 17.1, you may encounter above error when running the hardware test of the Low Latency Ethernet 10G MAC's dynamically generated 1G/2.5G/10G Ethernet with 1588 example design for Intel® Stratix® 10 device.

     

    Resolution

    To work around this problem, copy the "tod" folder from Quartus prime installation directory to the user's project directory.

    Quartus prime installation directory:

    <Quartus_installation_directory>/ip/altera/ethernet/alt_em10g32/example_design/LL10G_1G_2_5G_10G_1588v2/hwtesting/system_console/tod/

    User's project directory:

    <project_directory>/LL10G_1G_2_5G_10G_1588v2/hwtesting/system_console/tod/

    This problem is fixed starting with the Intel® Quartus® Prime Pro Edition Software version  17.1.1.

     

    Related Products

    This article applies to 1 products

    Intel® Stratix® 10 FPGAs and SoC FPGAs