Article ID: 000079060 Content Type: Troubleshooting Last Reviewed: 09/11/2012

What is the maximum output clock frequency for the HSTL Class I I/O standard in APEX II devices?

Environment

BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description The maximum HSTL Class I output clock frequency in APEX™ II devices is 125MHz.

The maximum HSTL Class II output clock frequency for APEX II devices is 200MHz. If your drive strength requirements do not preclude you from using HSTL Class II, use this I/O standard as an alternative to HSTL Class I.

If you require HSTL Class I output clock speeds greater then 125MHz, the Stratix® - series device families support higher speeds for HSTL Class I output functions.

Related Products

This article applies to 1 products

Apex™ II