Article ID: 000080096 Content Type: Troubleshooting Last Reviewed: 07/06/2015

Why does the Remote System Upgrade (RSU) function fail to revert back to the factory image in Arria V, Cyclone V and Stratix V devices?

Environment

BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

The RSU may fail to revert back to the factory image in Arria® V, Cyclone® V and Stratix® V devices due to the same reason that is documented in the following errata sheets:

One of the following invalid application configuration images may cause incorrect operation:  

  • A partially programmed application image
  • A blank application image
  • An application image assigned with a wrong start address
Resolution

To avoid this incorrect operation, use one of the following options: 

Related Products

This article applies to 15 products

Arria® V SX SoC FPGA
Cyclone® V ST SoC FPGA
Arria® V ST SoC FPGA
Arria® V GX FPGA
Arria® V GZ FPGA
Arria® V GT FPGA
Cyclone® V E FPGA
Stratix® V E FPGA
Cyclone® V SE SoC FPGA
Cyclone® V SX SoC FPGA
Cyclone® V GT FPGA
Stratix® V GX FPGA
Stratix® V GT FPGA
Cyclone® V GX FPGA
Stratix® V GS FPGA