Article ID: 000087076 Content Type: Troubleshooting Last Reviewed: 09/26/2011

Compilation Targeting a Stratix V Device Fails

Environment

  • Quartus® II Subscription Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT

    Critical Issue

    Description

    Designs that include a FIR Compiler and target a Stratix V device, do not compile even if you have a valid license for the IP core. Refer to Altera solution rd03082011_116 at http://www.altera.com/support/kdb/solutions/rd03082011_116.html.

    FIR Compiler designs that target a Stratix V device.

    Designs that include this IP core and target a Stratix V device cannot compile.

    Resolution

    To fix this issue, if you have a valid license for this IP core, follow these steps:

    1. Upgrade your Quartus II software installation to the 10.1 Service Pack 1 version.
    2. Apply Patch 1.19 to your Quartus II software installation.
    3. Regenerate your IP core and any others in your design that are affected by this issue.
    4. Recompile your design.

    Related Products

    This article applies to 1 products

    Stratix® V FPGAs